EVALUASI HAPUSAN DARAH TEPI DARAH K3EDTA SEGERA DI PERIKSA DAN DI TUNDA 24 JAM DALAM SUHU 2-8C
DOI:
https://doi.org/10.51804/jsh.v7i2.14357.79-84Abstract
Since specimen collection, preanalytical factors such as time and temperature could affect the peripheral blood smear morphology of erythrocytes, leukocytes, and thrombocytes. Delays are often caused by the limited number of medical personnel so work is not properly organized. This research is an observational qualitative descriptive study to determine the morphology of blood smears immediately checked and delay 24 hours at 2-8 ?. This study aims to determine the evaluation of K3EDTA venous peripheral blood smears immediately checked and delayed 24 hours at 2-8?. From 25 K3EDTA blood samples of Maarif Hasyim Latif Sidoarjo University students, it was found that there were no changes in the morphology of erythrocytes and platelets. Meanwhile, in leukocyte cells, changes occur in the neutrophil segment and stab granules, which is the granules fade, and the leukocyte nuclei can still be identified properly, so that do not affect the examination results. In conclusion, the Evaluation of the K3EDTA Peripheral Blood Smear was immediately checked and delay 24 Hours at the temperature of 2-8 ? has no change, which is still within normal limits.
Keywords : Blood Smear, Delayed, K3EDTA, Immediately checked
References
Ekanem, A. P., Udoh, A. J., & Inyang Etoh, A. P. 2012. Effect of Different Anticoagulants on Hematological Parameters of Oreochromis niloticu. IJSAT, 2(6), 17–20.
Faradisa, I. S., & Nurcahyo, E. 2016. Aplikasi Arduino Untuk Otomatisasi Apusan Darah Tepi Dan Pengecatan Menggunakan Pewarna Giemsa. Seniati, 221, 221–228.
Gunawardena, D., Jayaweera, S., Madhubhashini, G., Lokumarakkala, D., & Senanayake, S. 2017. Platelets: Still a Therapeutical Target for Haemostatic Disorders. Journal of Clinical Laboratory Analysis., 31(2).
Isti, R., Rofinda, Z. D., & Husni, H. (2018). Gambaran Morfologi Eritrosit Packed Red Cell Berdasarkan Waktu Penyimpanan Di Bank Darah RSUP Dr. M. Djamil Padang. Jurnal Kesehatan Andalas, 7(Supplement 2), 17. https://doi.org/10.25077/jka.v7i0.819
Kiswari, R. 2014. Hematologi Dan Transfusi. Erlangga.
Letelier, P., Guzmán, N., Medina, G., Calcumil, L., Huencho, P., Mora, J., Quiñones, F., Jara, J., Reyno, C., Farías, J. G., Belén, L. H., Brebi, P., Riquelme, I., & Martín, A. S. 2021. Workflow optimization in a clinical laboratory using lean management principles in the pre-analytical phase. Journal of Medical Biochemistry, 40(1), 26–32. https://doi.org/10.5937/jomb0-26055
Lippi, G., &Guidi, G. C. 2011. The preanalytical phase in quality assurance. Quality Assurance in the Pathology Laboratory: Forensic, Technical, and Ethical Aspects, October 2015, 3–13. https://doi.org/10.1201/b10601-3
Neogi, S., Mehndiratta, M., Gupta, S., & Puri,D. 2016. Pre-analytical phase in clinical chemistry laboratory. Journal of Clinical and Scientific Research, 5(3), 171. https://doi.org/10.15380/2277-5706.jcsr.15.062
Peng, L., Yang, H., Jiang, H., Su, J., & Peng, Z. 2001. Automated reticulocyte counting using the Sysmex RAM-1. Clinical and Laboratory Haematology, 23(2), 97–102. https://doi.org/10.1046/j.1365-2257.2001.00365.x
Sujud, S., Hardiasari, R., & Nuryati, A. 2015. Perbedaan Jumlah Trombosit Pada Darah EDTA Yang Segera Diperiksa dan PenundaanSelama 1 Jam di Laboratorium RSJ Grhasia Yogyakarta. Medical Laboratory Technology Journal, 1(2), 91. https://doi.org/10.31964/mltj.v1i2.21
Wankar, A. 2014. Study of determination of laboratory turnaround time in tertiary care hospital in India. International Journal of Research in Medical Sciences, 2(4), 1396. https://doi.org/10.5455/2320-6012.ijrms20141129
Downloads
Published
Issue
Section
License
Copyright (c) 2023 Jurnal SainHealth
This work is licensed under a Creative Commons Attribution 4.0 International License.
Jurnal SainHealth is licensed under Creative Commons Attribution 4.0 International License.
Under the following terms:
Attribution — You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.