PEMBUATAN DAN KARAKTERISASI ELEKTRODA SELEKTIF ION Pb2+ JENIS KAWAT PERAK TERLAPIS DENGAN IONOFOR 1,10-DIBENZYL-1,10-DIAZA-18-CROWN-6

Authors

  • Anton Yuntarso Universitas Maarif Hasyim Latif
  • Muji Harsini FMIPA UNAIR Surabaya
  • Dheasy Herawati Universitas Maarif Hasyim Latif
  • Khoirul Ngibad Universitas Maarif Hasyim Latif

DOI:

https://doi.org/10.51804/jsh.v2i1.173.21-30

Keywords:

ion selective electrode Pb2 , lead, wire coated, 1, 10-dibenzyl-1, 10-diaza-18-crown-6

Abstract

Lead concentration greater than 10 µg/L make health problem among other thing decrease in intelligence, nervous system disorders, so lead rapid analysis with high accuracy and precision is needed. The aim of this research are to know the composition of ESI-Pb2+ membrane silver wire coated type PVC/1,10-dibenzyl-1,10-diaza-18-crown-6, optimum pH condition and to study the characteristic electrode, such as Factor Nernst, range measurement, limit detection, accuracy and precision, selectivity, and blood serum sample accuracy. The result has shown that potensial measurement with Ag/AgCl reference electrode give the best membrane composition of 45 mg PVC, 90 mg NPOE, 10 mg KTCPB, 5 mg 1,10-dibenzyl-1,10-diaza-18-crown-6 in 0,5 ml THF solution. The optimum pH is 3-7 and gave 29,64 mV as Factor Nernst with range measurement 10-1–10-6 M, limit detection was noted at 1,28.10-6 M, and accuracy is 73% - 157% in 10-6–10-1 M Pb2+ solution with variation coefficient 0,70–1,2. The selectivity constanta is K_(i,j)^Pot < 1 toward K+, Ca2+, Mg2+, Na+, Cu2+ dan Fe3+ as interfering ions. Recovery percentage of Ion Selective Electrode Pb2+ silver wire coated type with PVC /1,10-dibenzyl-1,10-diaza-18-crown-6 to blood serum sample has shown 95% - 143% and 110%-117% compare with AAS.

References

Ali Amron, 2011, Elektroda Selektif Ion La3+ tipe Kawat Terlapis dengan Ionofor Senyawa Karboksimetoksi Tersier Butil Kalik[6] Arena, Tesis, Universitas Airlangga Surabaya

Anonim, 2013, Senyawa Timbal, http://asslita.blogspot.com/2013/09/v-behaviorurldefaultvmlo.html, diakses tanggal 7 September 2014.

Arous, O., Soud,S.F., Amara,M., Kerdjoudj,H., 2011, Efficient Facilitated Transport of Lead and Cadmium across a Plasticized Membrane Mediated by D2EHPA and TOPO, Materials Science and Aplication, 2, 612-623.

Atikah, 1994, Pembuatan dan Karakterisasi Elektroda Selektif Ion tipe Kawat Terlapis, Tesis, Institut Teknologi Bandung, 196p.

Bakırdere, S., Yaroğlu, T., Tırık, N., Demiröz, M., Fidan, A. K., Maruldalı, O., dan Karaca, A., 2013, Determination of As, Cd, and Pb in Tap Water and Bottled Water Samples by Using Optimized GFAAS System with Pd-Mg and Ni as Matrix Modifiers, Journal of Spectroscopy, 2013, 1–7.

Bakker, E., Buhlman, Pretsch, E., 1997, Carrier-Based Ion- Selective Electrode and Bulk Optodes, General Characteristic, Chem.Rev., 97, 3083-3132.

Carrijo, J. F. N., Luciano, C., Brasil, dan Coelho, N. M. M., 2005, Determination of Trace Lead in Waters by Flow Injection Hydride Generation Atomic Absorption Spectrometry, J. Braz. Chem. Soc., 16, 520-525.

Comeau, B., 2008, Plasticizer Alternatives for Use in Polymer Membrane Ion Selektive Electrodes, Disertation, Department of Chemistry, USA.

Diaz, M.T., dan Bakker, E., 2001, Effect of lipophilic Ion Exchanger Leaching on the Detection limit of Carrier Based Ion-Selective Electrode, Anal.Chem.,73, 5582-5589.

Darmono, 2001, Lingkungan Hidup dan Pencemaran, UI Press, Jakarta.

Eggins, B. R., 2002, Chemical Sensors and Biosensors, John Wiley & Sons Ltd, England.

Evan, A., 1991, Potensiometry and ion Selective Electrode, John Wiley & Son, Chichester, 304p.

Greenwood, N. N., dan Earnshaw, A., 1984, Chemistry of the Elements, Reed Educational and Professional Publishing, England.

Gupta, V. K., 2010, Potentiometric Sensors for Inorganic Anions Based on Neutral Carriers–An Invited Review Article, The Arabian Journal for Science and Engineering, 35, 7–25.

Harsini, M., 2008, Pembuatan Elektroda Komposit Polipirol/1,10-Dibenzyl-1,1o-Diaza-18-Crown-6 Secara Elektropolimerisasi Sebagai Sensor Voltametri Ion Hg2+ pada Orde Konsentrasi Pikomolar, Disertasi, Departemen Kimia, Bandung.

Harmita, 2004, Petunjuk Pelaksanaan validasi Metode dan Cara perhitunghannya, Majelis Ilmu Kefarmasian, Vol.I, No.3, UI Jakarta.

Huang, M., Ma, X., Li, X., 2009, Lead (II) ion-selective Electrode Based on Polyaminoanthraquinone Particles with intrinsic Conductivity, Talanta, 498-505.

Hynek, D., Prasek, J., Pikula, J., Adam, V., Hajkova, P., Krejcova, L., Trnkova, L., Sochor, J., Pohanka, M., Hubalek, J., Beklova, M., Vrba, R., dan Kizek, R., 2011, Electrochemical Analysis of Lead Toxicosis in Vultures, Int. J. Electrochem. Sci., 6, 5980 – 6010.

Janata, J, 2009, Principles of Chemical Sensors; second edition, Springer Science + Business Media, London.

Kricheldorf, H. R., Nuyken, O., dan Swift, G., 2005, Handbook of Polymer Synthesis; Second Edition, Marcel Dekker, New York.

Khopkar, S. M., 1998, Basic Concept of Analytical Chemistry, New Age International Ltd, New Delhi.

Mousavi, M.F., Sahari, S., Alizadeh, A.,Shamsipur, M., 2000, Lead Ion-Selective Membrane Electrode Based on 1,10-Dibenzyl-1,10-Diaza-18-Crown-6, Analytica Chimica Acta 414, 189-194.

Masadome, T., Wakida, S., Kawabata, Y., Imato, T., dan Ishibashi, N., 1992, Contribution of Plasticizer to Response of Surfactant-Selective Plasticized Polyvinyl chloride) Membrane Electrode by Using Ion-Sensitive Field-Effect Transistor, Analytical Sciences, 8, 89–91.

Matta, Wilbraham , Staley, 1996, General, Organic, and Biological chemistry, Health and Company, Toronto.

Mhammedi, M. A. E., Achak, M., dan Bakasse, M., 2013, Evaluation of A Platinum Electrode Modiï¬ed with Hydroxyapatite in the Lead(II) Determination in A Square Wave Voltammetric Procedure, Arabian Journal of Chemistry, 6, 299–305.

Meyerhoff, M. E., dan Opdycke, W. N., 1986, Advances in Clinical Chemistry, Academic Press INC, London.

Neira, Maria, 2010, Childhood Lead Poisoning, World Health Organization (WHO).

Palar Heryando, 1994, Pencemaran dan Toksikologi Logam Berat, Rineka Cipta, Jakarta.

Parveen, N., dan Rohan, Y., 2011, Spectrophotometric Determination of Some Environmental Samples, Journal of Environmental Research And Development, 6, 57–62.

Patrick, S. G., 2005, Practical Guide to Polyvinyl Chloride, Rapra Technology Limted, Shawbury.

Rounaghi, G. H., Mohajeri, M., Ashrafi, S., Ghasemi, H., Sedaghat, S., dan Tavakoli, M., 2007, Complex Formation of 1,10-Dibenzyl-1,10-diaza-18-crown-6 with Ni2+, Cu2+, Ag+ and Cd2+ Metal Cations in Acetonitrile–dimethylformamide Binary Solutions, Journal of Inclusion Phenomena and Macrocyclic Chemistry, 58, 1-6.

Shemirani, F., Abkenar, S. D., dan Khatouni, A., 2004, Determination of Trace Amounts of Lead and Copper in Water Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction, Bull. Korean Chem. Soc., 25, 1133–1136.

Suyanta, 2013, Potensiometri, UNY Press, Yogyakarta.

Talebi, S. M., dan Safigholi, H., 2006, Determination of Lead in Water Resources by Flame Atomic Absorption Spectrometry After Pre-concentration with Ammonium Pyrrolidinedithiocarbamate Immobilized on Surfactant-Coated Alumina, J. Serb. Chem. Soc., 72, 585–590.

Ginnynorman, 2010, Polyvinyl Chloride, http://ginnynorman.wordpress.com/, diakses tanggal 15 September 2014.

Wang, N., Raza, A., Si, Y., Yu, J., Sun, G., dan Ding, B., 2013, Tortuously Structured Polyvinyl Chloride/Poly Urethane Fibrous Membranes for High-Efficiency Fine Particulate Filtration, Journal of Colloid and Interface Science, 398, 240–246.

Zolotov, Y.A., 1997, Macrocyclic Compounds in Analytical Chemistry, John Wiley and Sons, Inc, New York.

Downloads

Published

2018-03-28

Issue

Section

Articles